Cross-Model Agreement as a Deployment-Time Reliability Signal for Automatic Polyp Segmentation

Siddharth Gupta, Jitin Singla

arxiv Score 8.2

Published 2026-09-09 · First seen 2026-09-10

General AI

Abstract

In real-time colonoscopy, ground-truth annotations are unavailable at inference, so polyp segmentation models can fail silently. We propose Referee-Based Quality Estimation (RBQE), a reference-free framework measuring agreement between a primary segmentation model and an independently trained referee on the same image. RBQE is evaluated on a standardized 1,223-image external benchmark drawn from four public datasets, using four referee configurations chosen to separate two design axes: referee independence and architectural diversity. Using a common Agreement Dice descriptor, a same-architecture referee differing from the primary model only in random initialization already yields a useful reliability signal (ROC-AUC = 0.923), showing that independent training alone is sufficient. Cross-architecture referees improve further: SegFormer-B0 achieves the strongest performance (ROC-AUC = 0.960), significantly outperforming the same-architecture control and UNet++, and exceeding a representative Test-Time Augmentation baseline by 0.055 ROC-AUC under an identical protocol, whereas a prompt-coupled MedSAM referee underperforms despite maximal architectural diversity. Because empty-mask agreement is trivially separable, we also report a restricted evaluation excluding such cases: ROC-AUC falls to 0.876 (SegFormer-B0, 1,046 images) and 0.783 (same-architecture control, 975 images), yet RBQE's margin over both baselines widens on this identical subset. RBQE additionally increases the mean Dice of retained predictions as low-agreement cases are progressively rejected, supporting selective prediction, and requires only one additional deterministic referee forward pass at inference. Our study therefore supports cross-model agreement as a practical, interpretable reliability framework for automated polyp segmentation.

Workflow Status

Review status
pending
Role
unreviewed
Read priority
soon
Vote
Not set.
Saved
no
Collections
Not filed yet.
Next action
Not filled yet.

Reading Brief

No structured notes yet. Add `summary_sections`, `why_relevant`, `claim_impact`, or `next_action` in `papers.jsonl` to enrich this view.

Why It Surfaced

No ranking explanation is available yet.

Tags

No tags.

BibTeX

@article{gupta2026cross,
  title = {Cross-Model Agreement as a Deployment-Time Reliability Signal for Automatic Polyp Segmentation},
  author = {Siddharth Gupta and Jitin Singla},
  year = {2026},
  abstract = {In real-time colonoscopy, ground-truth annotations are unavailable at inference, so polyp segmentation models can fail silently. We propose Referee-Based Quality Estimation (RBQE), a reference-free framework measuring agreement between a primary segmentation model and an independently trained referee on the same image. RBQE is evaluated on a standardized 1,223-image external benchmark drawn from four public datasets, using four referee configurations chosen to separate two design axes: referee i},
  url = {https://arxiv.org/abs/2609.10495},
  keywords = {cs.CV, cs.LG},
  eprint = {2609.10495},
  archiveprefix = {arXiv},
}

Metadata

{}